Product Description:
high quality
Made of high-quality materials for durability
With this conversion kit installed, y generator will be able to use LPG-propane or CNG methane gas without any on generator’s (you can still use ). This kit is only suitable for low pressure gases such as domestic propane.
Conversion kits include a pressure regulator and a gas carburetor. The pressure regulator reduces the propane gas or natural gas from high to low and stabilizes the gas pressure before entering the gas carburetor and then the engine; when the generator stops working, the pressure regulator also shuts off the gas supply, So it’s safe, you don’t have to worry about the gas still going into the engine after the generator goes out.
After the conversion, the generator power remains unchanged. When using propane or methane gas, power depends on generator quality and gas quality.
Tr , Low Pressure Propane LPG-Gas/Methane CNG Gas (use only at a time)
Weight: Approx. 600 grams
Accessories: It is mainly designed to replace a For Honda 68F generator, but please check our gas carburetor sizes to see if it can replace your generator carburetor, if so, it will fit; if not, put Not suitable.
EASY INSTALLATION: Just replace your generator carburetor with our gas carburetor (please double check if your generator carburetor is replaceable before buying!)
NOTE: It is your responsibility to for ENSURE that the use of this conversion kit complies with your laws.
NOTE: When starting with propane or methane gas, make sure there is no in the carburetor or the generator will not work properly.
Instructions for use:
The new does not contain oil, please add 0.9L before use.
(The instructions in Chinese translation below may be confusing, don’t worry, just use propane (or methane) gas as an alternative , when you use propane (or methane) gas, it’s using , just be careful, start using When using propane (methane) gas, make sure there is no in the carburetor; when using , make sure there is no propane (methane) gas in the carburetor, simple!)
How to start the generator:
– Start with propane gas:
. Turn off the switch (make sure there is no in the carburetor)
2. Turn on the propane gas switch.
3. Close the throttle valve switch, pull it 3 to 4 times, open the throttle valve to the middle and then fully open it; when the engine is hot, it will open and start directly.
4. Turn on the power switch
5. Pull the start rope 4-5 times (throttle valve closed or open to the middle) / (key) generator start
6. After starting, open the throttle switch on the carburetor mixing device
7. The generator starts normally
Generator shutdown steps: Turn off the propane gas tank switch first, then turn off the generator switch.
– Start with :
. Turn off the propane gas
2. Turn on
3. Turn off the choke switch on the carburetor
4. Turn on the power switch
5. Pull the starting rope several times, the generator starts
6. After starting, open the throttle switch on the carburetor mixing device
7. The generator starts normally
Notice:
. Do not use indoors, if necessary, please for ENSURE good ventilation
2. Do not use when the intake pressure is too high or too low, the working pressure should be between 2.8~4.8
3. It cannot be determined whether there is air leakage at the outlet connection of the gas tank or the gas connection of the pipeline
4. Do not turn the gas storage tank upside down to prevent gas impurities from entering the gas
Package Included:
* Generator Conversion Kit
Note:
.The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
2.Please allow slight manual measurement deviation for the data.
– Designed to allow petrol generators with 2-5KW power to use LPG-propane or CNG methane alongside without affecting the original system.
– Kit includes a zero-pressure regulator an gas carburetor, ensuring stable gas pressure and safe operation.
– Power output of the generator remains unchanged after the conversion; dependent on the quality of both the generator and the gas used.
– Compatible with Tr , Low Pressure Propane LPG-Gas/Methane CNG Gas (only type can be used at a time).
– Easy installation by replacing the generator carburetor with the provided gas carburetor. Please verify compatibility before purchase.
User Reviews
Be the first to review “Dual fuel carburetor LPG-CNG conversion kit for Petrol Generators 2-5KW manual choke to Use Methane CNG/Propane LPG-Gas”
$30.89

There are no reviews yet.